Home > Products > Steam Traps > Thermostatic > Thermostatic

 

Thermostatic Steam Traps

Thermostatic Steam Traps

These steam traps operate by the temperature difference between steam and condensate.

Operating Pressure Range: 0.01 - 3.2 MPaG
Operating Temperature Range: 0 - 240 °C

Color Pamphlet PDF BALANCED PRESSURE THERMOSTATIC STEAM TRAPS Pamphlet (704 KB)

More DetailProduct Details


L21S photo

L21S

Specifications
Manual

• Max. Operating Pressure: 2.1 MPaG
• Max. Operating Temperature: 235℃
• L21SC features an integral check valve
• Body: Carbon Steel
L32S photo

L32S

Specifications
Manual

• Max. Operating Pressure: 3.2 MPaG
• Max. Operating Temperature: 240℃
• L32SC features an integral check valve
• Body: Carbon Steel
LV13L photo

LV13L

Specifications
Manual

• Max. Operating Pressure: 1.3 MPaG
• Max. Operating Temperature: 200℃
• Brass Construction Angled Body
LV13N photo

LV13N

Specifications
Manual

• Max. Operating Pressure: 1.3 MPaG
• Max. Operating Temperature: 200℃
• Body: Brass
LV21 photo

LV21

Specifications
Manual

• Max. Operating Pressure: 2.1 MPaG
• Max. Operating Temperature: 235℃
• Body: Cast Stainless Steel
FL21 QuickTrap® photo

FL21 QuickTrap®

Specifications
Manual

• Max. Operating Pressure: 2.1 MPaG
• Max. Operating Temperature: 235℃
• Universal flange
• FL21C features an integral check valve
• Body: Cast Steel
FL32 QuickTrap® photo

FL32 QuickTrap®

Specifications
Manual

• Max. Operating Pressure: 3.2 MPaG
• Max. Operating Temperature: 240℃
• Universal flange
• FL32C features an integral check valve
• Body: Cast Steel

Always check the specification PDFs for the exact product specification available in your region.


Merits and featuresBenefits and Features

All L, LV and FL series models employ a thermoliquid-filled X-element, which acts as the valve.

Improved Productivity
The X-element discharges hot air as well as causing the rapid discharge of low temperature air and cold condensate. This encourages the inflow of steam, thereby reducing start-up times.
Protects Equipment
The valve remains opens even in the event of failure of the 'fail open' construction X-element, which means that the equipment can continue operating without any interruption in heating.
Long Service Life
Any rust or scale entering the trap from the piping is discharged together with the condensate through the large valve opening, greatly reducing the chance of a build-up of rust or scale that would obstruct the valve opening.

Application areasApplication Areas

Suitable for use in a variety of applications.

Main Applications
Air conditioning, steam tracers, steam heating equipment, etc.