TLV Co. Ltd
TLV CORPORATION

13901 South Lakes Drive
Charlotte, NC 28273-6790, USA
Phone: [1]-704-597-9070


Large Capacity Float Steam Traps

Large Capacity Float Steam Traps

Large capacity steam traps with a maximum discharge capacity of 150 t/h.

Operating Pressure Range: Vacuum - 650 psig
Operating Temperature Range: 32 - 800 °F

Color Pamphlet PDF Free Float Steam Trap Series Color Pamphlet (2482 KB)
Color Pamphlet PDF Free Float and Other Float Steam Trap Discharge Capacities Color Pamphlet (84 KB)

More DetailProduct Details


J10 photo

J10

J10 Specification PDF (97 KB) Specification

Extra-large capacity float steam trap. FLOATDYNAMIC® feature uses a free float as a pilot valve. Discharge capacity of up to approximately 150,000 lb of condensate per hour.
JH15 photo

JH15

JH15 Specification PDF (186 KB) Specification

Extra-large capacity high pressure float steam trap. Maximum operating pressure is up to 650 psig. FLOATDYNAMIC® feature uses a free float as a pilot valve. Discharge capacity of up to approximately 350,000 lb of condensate per hour.
JL9X / JLH9X photo

JL9X / JLH9X

JL9X / JLH9X Specification PDF (185 KB) Specification

Lever Float with Dual Valve mechanism for high capacity, for use on process equipment. Features thermostatic air venting. Discharge capacity of approximately 39,970 lb of condensate per hour.
JL14X / JLH14X photo

JL14X / JLH14X

JL14X / JLH14X Specification PDF (159 KB) Specification

Lever Float with Dual Valve mechanism for high capacity, for use on process equipment. Features thermostatic air venting. Discharge capacity of approximately 140,000 lb of condensate per hour.
 

Always check the specification PDFs for the exact product specification available in your region.


Merits and featuresBenefits and Features

Improved Heating Efficiency (J10/JH15)
Float dynamic construction, with its larger valve opening, discharges large amount of condensate from steam heating equipment that uses greater amounts of steam than average.
The free float responds with great sensitivity to the flow of condensate, rapidly initiating condensate discharge as soon as condensate enters .
Improved Heating Efficiency (JL/JLH)
Float with lever construction, with a double-seated valve, discharges large amount of condensate from steam heating equipment that uses greater amounts of steam than average.
The built-in X-element (models with 'X') functions as an air vent, discharging both cool and hot air. As a result, the steam chamber inside the equipment contains only steam, which allows the equipment to achieve optimized heating performance.

Application areasApplication Areas

Suitable for processes that use large quantities of steam in continuous operation.

Main Applications
Reboilers, large heat exchangers.