- Home
- Products
- Pressure Reducing Valves
- Clean Steam Direct-Acting Pressure Reducing Valve
Fluid Control Equipment
Clean Steam Direct-Acting Pressure Reducing Valve
DR8 Series
Compact stainless steel direct-acting PRV for clean steam
Compact pressure reducing valve for use on autoclaves, sterilizers, humidifiers, etc. in the pharmaceutical, medical, food and other industries.
Benefits and Features
Direct-acting pressure reducing valve developed for clean steam
- Easy access to internal parts simplifies cleaning and reduces maintenance cost.
- Internal buff-polishing with an additional interior and exterior electro-polish option to 0.4 μm Ra for improved resistance to bacterial growth.
- Wetted parts are stainless steel and USP or FDA compliant rubber or resin with high durability and corrosion resistance for long service life.
Lightweight, compact design with a long service life
- High flow rate for its class.
- Double-guided valve for stable operation.
Application Areas
Reducing the pressure of clean steam and pure steam systems
Product Details
Model | Photo | Connection | Body Material | PMO (MPaG) | TMO (°C) | Internal Finishing | External Finishing | Primary Pressure (MPaG) | Secondary Pressure (MPaG) | Maximum Flow Rate (kg/h) | Specifications | Manual |
---|---|---|---|---|---|---|---|---|---|---|---|---|
DR8-P | ![]() | Clamp End | Stainless Steel (ASTM A182 Gr.F316L) | 0.8 | 175 | 0.8 μm Ra Buff-polished | 25 μm Ra electro-polished | 0.2 - 0.8 | 0.018 - 0.6 | 1740 | Specifications | Manual |
DR8-EP | Buff-polished then 0.4 μm Ra electro-polished |
- PMO = Maximum Operating Pressure
- TMO = Maximum Operating Temperature
The latest version of each product's instruction manual can be found on this page.