- Home
 - Products
 - Pressure Reducing Valves
 - Clean Steam Direct-Acting Pressure Reducing Valve
 
Fluid Control Equipment
Clean Steam Direct-Acting Pressure Reducing Valve
DR8 Series

Compact stainless steel direct-acting PRV for clean steam
Compact pressure reducing valve for use on autoclaves, sterilizers, humidifiers, etc. in the pharmaceutical, medical, food and other industries.
Benefits and Features
- Wetted parts are stainless steel and USP or FDA compliant rubber or resin with high durability and corrosion resistance for long service life
 - Double-guided valve for stable operation
 - Internal buff-polishing with an additional interior and exterior electro-polish option to 0.4 μm Ra for improved resistance to bacterial growth
 - Easy to operate and adjust
 - Easy access to internal parts simplifies cleaning and reduces maintenance cost
 - High flow rate for its class.
 
Application Areas
Reducing the pressure of clean steam and pure steam systems
Product Details
| Model | Photo | Connection | Body Material | PMO (MPaG) | TMO (°C) | Internal Finishing | External Finishing | Primary Pressure (MPaG) | Secondary Pressure (MPaG) | Maximum Flow Rate (kg/h) | Specifications | Manual | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DR8-P | ![]()  | Clamp End | Stainless Steel  (ASTM A182 Gr.F316L)  | 0.8 | 175 | 0.8 μm Ra Buff-polished | 25 μm Ra electro-polished | 0.2 - 0.8 | 0.018 - 0.6 | 1740 | Specifications | Manual | 
| DR8-EP | Buff-polished then 0.4 μm Ra electro-polished | |||||||||||
- PMO = Maximum Operating Pressure
 - TMO = Maximum Operating Temperature
 
The latest version of each product's instruction manual can be found on this page.