Free Float® Steam Traps (Medium / High Pressure)

Free Float® steam traps that offer continuous discharge and are optimal for processes. Mid to high pressure use, up to 120 barg. Some models for use in main lines also available.
Operating Pressure Range: 0.1 - 120 barg
Operating Temperature Range: 0 - 530 °C
Product Selection by Application
Product Details
Benefits and Features
- Improved Efficiency of Heating Equipment
- The Free Float® rises and sinks as the flow of condensate fluctuates, opening the valve to discharge condensate and closing off the valve when steam enters.
- The built-in X-element (model names including 'X') functions as an air vent, discharging both cool and hot air. As a result, the steam chamber inside the equipment contains only steam, which allows the equipment to achieve optimized heating performance.
- The built-in bimetal (model names including 'B') functions as an air vent, discharging initial cold air for rapid start-up.
- Long Service Life, Excellent Durability
- The spherical Free Float® rotates during operation, allowing any point on its surface to act as the valve seal and thus ensuring long service life.
- Protects Equipment
- 'Fail Open' Design: The X-element is designed to fail open so that the valve remains open even in the event of failure.
- Also for Use on Mid/High-Pressure Main Lines
- The JH7 series employs the same 3-point seating construction found in products for use on main lines. The float is held tightly against the valve opening even under small condensate loads such as in superheated steam lines, so no steam is allowed to escape.
Application Areas
Especially suitable for steam processes.
- Main Applications
- Heat exchangers, reactor kettles, vulcanizing pans, jacketed kettles, roller heat exchangers, cylinder dryers, steam main lines (some models), etc.
Product Selection by Application
This guide shows the most suitable TLV steam traps for an array of applications.
Start by selecting an application from the drop-down menu at the top, then search for your desired operation principle, pressure category, and other special features to find the right steam trap.
Steam Mains and Steam Headers
Steam Mains and Steam Headers |
Product Features
Special Features for Pipe End Traps
|
|||
---|---|---|---|---|
Operation Principle | Pressure Category*1 (barg) | Remark | Product Series | Further Reference |
Continuous discharge (Energy saving model) | Up to 10 | With bypass valve | J3S-X-BV, J3S-X-PB | Steam Traps with Bypass Valve |
Up to 21 | - | SS Series (SS1, SS3) | Free Float® Steam Traps for Main Lines | |
With bypass valve | J3S-X-RV | Steam Traps with Bypass Valve | ||
Up to 32 | - | SS Series (SS5) | Free Float® Steam Traps for Main Lines | |
JH3S-B | Free Float® Steam Traps (Medium / High Pressure) | |||
QuickTrap with universal connector | FS Series | Free Float® Steam Traps for Main Lines | ||
Up to 46 | QuickTrap with universal connector | FS Series (FS5H) | ||
- | SS Series (SS5H) | |||
JH-B Series | Free Float® Steam Traps (Medium / High Pressure) | |||
Up to 65 | SH Series | Free Float® Steam Traps for Main Lines | ||
JH-P Series | Free Float® Steam Traps (Medium / High Pressure) | |||
Up to 100 | JH7RH-B | |||
Up to 120 | JH7RH-P | |||
Cyclic operation (Energy saving model) | Up to 32 | - | L Series | Thermostatic Steam Traps |
QuickTrap with universal connector | FL Series | |||
Intermittent operation | Up to 13 | Inline replaceable valve module | A3N | Disc-Type Steam Traps |
Up to 46 | QuickTrap with universal connector & inline replaceable valve module | FP46UC | ||
Up to 65 | Inline replaceable valve module | P Series*2 | ||
Up to 260 | HR Series |
*1 Operating pressures vary between different models of the same series. For details please refer to individual Specification Data Sheets (SDS).
*2 Except P46S and P21S ver.C.
Equipment and Processes
Equipment and Processes |
Product Features
|
||||
---|---|---|---|---|---|
End-usage | Pressure Category*2 (barg) | Remark | Series | Further Reference | |
Heating |
|
Up to 10 | With bypass valve | J3S-X-BV, J3S-X-PB | Steam Traps with Bypass Valve |
Up to 22 | - | SJFX Series | Free Float® Steam Traps (Low Pressure) | ||
Up to 21 | JX Series | ||||
With bypass valve | J3S-X-RV | Steam Traps with Bypass Valve | |||
For sterile processes | LV6 | Clean Steam Traps | |||
SS5P | |||||
Up to 32 | For small size equipment | L Series | Thermostatic Steam Traps | ||
- | JH-X Series | Free Float® Steam Traps (Medium / High Pressure) | |||
Vaporization |
|
Up to 46 | - | JH-B Series | |
Up to 32 | Up to 400°C | SJHB Series | |||
Up to 65 | - | SH Series | |||
JH-P Series | |||||
Up to 100 | JH7RH-B | ||||
Up to 120 | JH7RH-P | ||||
Drying |
|
Up to 32 | - | JL Series | Large Capacity Float Steam Traps |
Up to 46 | JL15 Series | ||||
Up to 32 | Up to 400°C | SJHB Series | Free Float® Steam Traps (Low Pressure) | ||
|
Up to 22 | - | SJFX Series | ||
Up to 21 | JX Series | ||||
Up to 32 | For small size equipment | L Series | Thermostatic Steam Traps | ||
- | SJHX Series | Free Float® Steam Traps (Medium / High Pressure) | |||
*1 Depending on the operation condition, the indicated equipment may be subject to "stall" (see *3 below). In such cases, GT Series PowerTraps are required. GT Series PowerTraps are steam traps that feature a pump function. | GT Series | PowerTraps |
*2 Operating pressures vary between different models of the same series. For details please refer to individual Specification Data Sheets (SDS).
*3 "Stall" is a phenomenon where the internal pressure of an equipment falls below the back pressure on the outlet side, resulting in back-up of condensate that cannot be discharged by conventional steam traps. "Stall" can cause damage such as uneven/incomplete product heating, corrosion and waterhammer.
Heat Exchangers and Air Conditioning
Heat Exchangers and Air Conditioning |
Product Features
|
|||
---|---|---|---|---|
End-usage | Pressure Category*2 barg | Remark | Series | Further Reference |
|
Up to 10 | With bypass valve | J3S-X-BV, J3S-X-PB | Steam Traps with Bypass Valve |
Up to 22 | - | SJFX | Free Float® Steam Traps (Low Pressure) | |
Up to 21 | JX Series | |||
With bypass valve | J3S-X-RV | Steam Traps with Bypass Valve | ||
Up to 32 | For small size equipment | L Series | Thermostatic Steam Traps | |
- | SJHX Series | Free Float® Steam Traps (Medium / High Pressure) | ||
*1 Depending on the operation condition, the indicated equipment may be subject to "stall" (see *3 below). In such cases, GT Series PowerTraps are required. GT Series PowerTraps are steam traps that feature a pump function. | GT Series | PowerTraps |
*2 Operating pressures vary between different models of the same series. For details please refer to individual Specification Data Sheets (SDS).
*3 "Stall" is a phenomenon where the internal pressure of an equipment falls below the back pressure on the outlet side, resulting in back-up of condensate that cannot be discharged by conventional steam traps. "Stall" can cause damage such as uneven/incomplete product heating, corrosion and waterhammer.
Trace and Tank Coils
Trace and Tank Coils |
Product Features
Special Features for Measurement Instruments
|
|||
---|---|---|---|---|
End-usage | Control Temperature Category | Remark | Series | Further Reference |
Insulation jackets | - | - | SS Series | Free Float® Steam Traps for Main Lines |
L Series | Thermostatic Steam Traps | |||
A3N | Disc-Type Steam Traps | |||
P Series | ||||
QuickTrap with universal connector | FS Series | Free Float® Steam Traps for Main Lines | ||
FL Series | Thermostatic Steam Traps | |||
FP46UC | Disc-Type Steam Traps | |||
Pipe trace heating | Controlled temperature above 80°C | - | SS Series | Free Float® Steam Traps for Main Lines |
L Series | Thermostatic Steam Traps | |||
A3N | Disc-Type Steam Traps | |||
P Series | ||||
QuickTrap with universal connector | FS Series | Free Float® Steam Traps for Main Lines | ||
FL Series | Thermostatic Steam Traps | |||
FP46UC | Disc-Type Steam Traps | |||
Controlled temperature up to 80°C | Utilizes sensible heat | LEX3N-TZ | Temperature Control Steam Traps | |
Instrumentation trace heating | Controlled temperature above 80°C | - | P21S ver.C | Disc-Type Steam Traps |
P46S | ||||
LV Series | Thermostatic Steam Traps | |||
Controlled temperature up to 80°C | Utilizes sensible heat | LEX3N-TZ | Temperature Control Steam Traps |