Product Selection by Application
-
Steam Mains and
Steam Headers -
Equipment and Processes
-
Heat Exchangers and
Air Conditioning -
Trace and Tank Coils
Product Features
- Models categorized for "energy saving" have minimal steam loss
- Tight seal even under minimal load
- Operation not receptive to environmental influences (wind, rain/snow)
- Initial air venting feature
Special Features for Pipe End Traps
- Initial air venting feature
- Swift discharge of high condensate load at start-up
- No condensate back-up owing to continuous discharge
Operation Principle | Pressure Category*1 (barg) | Remark | Product Series | Further Reference |
---|---|---|---|---|
Continuous discharge (Energy saving model) | Up to 10 | With bypass valve | J3S-X-BV, J3S-X-PB | Steam Traps with Bypass Valve |
Up to 21 | - | SS Series (SS1, SS3) | Free Float® Steam Traps for Main Lines | |
With bypass valve | J3S-X-RV | Steam Traps with Bypass Valve | ||
Up to 32 | - | SS Series (SS5) | Free Float® Steam Traps for Main Lines | |
JH3S-B | Free Float® Steam Traps (Medium / High Pressure) | |||
QuickTrap with universal connector | FS Series | Free Float® Steam Traps for Main Lines | ||
Up to 46 | QuickTrap with universal connector | FS Series (FS5H) | ||
- | SS Series (SS5H) | |||
JH-B Series | Free Float® Steam Traps (Medium / High Pressure) | |||
Up to 65 | SH Series | Free Float® Steam Traps for Main Lines | ||
JH-P Series | Free Float® Steam Traps (Medium / High Pressure) | |||
Up to 100 | JH7RH-B | |||
Up to 120 | JH7RH-P | |||
Cyclic operation (Energy saving model) | Up to 32 | - | L Series | Thermostatic Steam Traps |
QuickTrap with universal connector | FL Series | |||
Intermittent operation | Up to 13 | Inline replaceable valve module | A3N | ThermoDyne® Disc-Type Steam Traps |
Up to 46 | QuickTrap with universal connector & inline replaceable valve module | FP46UC | PowerDyne® Disc-Type Steam Traps | |
Up to 65 | Inline replaceable valve module | P Series*2 | ||
Up to 260 | HR Series |
*1 Operating pressures vary between different models of the same series. For details please refer to individual Specification Data Sheets (SDS).
*2 Except P46S and P21S ver.C.
Product Features
- No condensate back-up owing to continuous discharge
- Self-modulating discharge as condensate load varies
- Initial air venting feature
- High back pressure tolerance (Condensate discharge capacity even at small differential pressure)
- "Fail open" to avoid condensate back-up under any circumstances
End-usage | Pressure Category*2 (barg) | Remark | Series | Further Reference | |
---|---|---|---|---|---|
Heating |
|
Up to 10 | With bypass valve | J3S-X-BV, J3S-X-PB | Steam Traps with Bypass Valve |
Up to 22 | - | SJFX Series | Free Float® Steam Traps (Low Pressure) | ||
Up to 21 | JX Series | ||||
With bypass valve | J3S-X-RV | Steam Traps with Bypass Valve | |||
For sterile processes | LV6 | Clean Steam Traps | |||
SS5P | |||||
Up to 32 | For small size equipment | L Series | Thermostatic Steam Traps | ||
- | JH-X Series | Free Float® Steam Traps (Medium / High Pressure) | |||
Vaporization |
|
Up to 46 | - | JH-B Series | |
Up to 32 | Up to 400°C | SJHB Series | |||
Up to 65 | - | SH Series | |||
JH-P Series | |||||
Up to 100 | JH7RH-B | ||||
Up to 120 | JH7RH-P | ||||
Drying |
|
Up to 32 | - | JL Series | Large Capacity Float Steam Traps |
Up to 46 | JL15 Series | ||||
Up to 32 | Up to 400°C | SJHB Series | Free Float® Steam Traps (Low Pressure) | ||
|
Up to 22 | - | SJFX Series | ||
Up to 21 | JX Series | ||||
Up to 32 | For small size equipment | L Series | Thermostatic Steam Traps | ||
- | SJHX Series | Free Float® Steam Traps (Medium / High Pressure) | |||
*1 Depending on the operation condition, the indicated equipment may be subject to "stall" (see *3 below). In such cases, GT Series PowerTraps are required. GT Series PowerTraps are steam traps that feature a pump function. | GT Series | PowerTraps |
*2 Operating pressures vary between different models of the same series. For details please refer to individual Specification Data Sheets (SDS).
*3 "Stall" is a phenomenon where the internal pressure of an equipment falls below the back pressurae on the outlet side, resulting in back-up of condensate that cannot be discharged by conventional steam traps. "Stall" can cause damage such as uneven/incomplete product heating, corrosion and waterhammer.
Product Features
- No condensate back-up owing to continuous discharge
- Self-modulating discharge as condensate load and pressure changes
- Initial air venting feature
- Quiet operation
End-usage | Pressure Category*2 barg | Remark | Series | Further Reference |
---|---|---|---|---|
|
Up to 10 | With bypass valve | J3S-X-BV, J3S-X-PB | Steam Traps with Bypass Valve |
Up to 22 | - | SJFX | Free Float® Steam Traps (Low Pressure) | |
Up to 21 | JX Series | |||
With bypass valve | J3S-X-RV | Steam Traps with Bypass Valve | ||
Up to 32 | For small size equipment | L Series | Thermostatic Steam Traps | |
- | SJHX Series | Free Float® Steam Traps (Medium / High Pressure) | ||
*1 Depending on the operation condition, the indicated equipment may be subject to "stall" (see *3 below). In such cases, GT Series PowerTraps are required. GT Series PowerTraps are steam traps that feature a pump function. | GT Series | PowerTraps |
*2 Operating pressures vary between different models of the same series. For details please refer to individual Specification Data Sheets (SDS).
*3 "Stall" is a phenomenon where the internal pressure of an equipment falls below the back pressure on the outlet side, resulting in back-up of condensate that cannot be discharged by conventional steam traps. "Stall" can cause damage such as uneven/incomplete product heating, corrosion and waterhammer.
Product Features
- Models categorized as "energy saving" have minimal steam loss
- Tight seal even under minimal load
- Operation not receptive to environmental influences (wind, rain/snow)
Special Features for Measurement Instruments
- Small and lightweight construction
End-usage | Control Temperature Category | Remark | Series | Further Reference |
---|---|---|---|---|
Insulation jackets | - | - | SS Series | Free Float® Steam Traps for Main Lines |
L Series | Thermostatic Steam Traps | |||
A3N | ThermoDyne® Disc-Type Steam Traps | |||
P Series | PowerDyne® Disc-Type Steam Traps | |||
QuickTrap with universal connector | FS Series | Free Float® Steam Traps for Main Lines | ||
FL Series | Thermostatic Steam Traps | |||
FP46UC | PowerDyne® Disc-Type Steam Traps | |||
Pipe trace heating | Controlled temperature above 80°C | - | SS Series | Free Float® Steam Traps for Main Lines |
L Series | Thermostatic Steam Traps | |||
A3N | ThermoDyne® Disc-Type Steam Traps | |||
P Series | PowerDyne® Disc-Type Steam Traps | |||
QuickTrap with universal connector | FS Series | Free Float® Steam Traps for Main Lines | ||
FL Series | Thermostatic Steam Traps | |||
FP46UC | PowerDyne® Disc-Type Steam Traps | |||
Controlled temperature up to 80°C | Utilizes sensible heat | LEX3N-TZ | Temperature Control Steam Traps | |
Instrumentation trace heating | Controlled temperature above 80°C | - | P21S ver.C | PowerDyne® Disc-Type Steam Traps |
P46S | ||||
LV Series | Thermostatic Steam Traps | |||
Controlled temperature up to 80°C | Utilizes sensible heat | LEX3N-TZ | Temperature Control Steam Traps |