Applicable Fluids and Maximum Operating Temperature (TMO)
Model | Max. operating temperature TMO [°C] | Applicable fluid | |||
---|---|---|---|---|---|
Steam | Hot water | Water | Air | ||
CK3M | 220°C | 〇 | - | - | - |
CK3T | 185°C | 〇 | 〇 | - | - |
CK3R | 90°C | - | 〇 | 〇 | 〇 |
CK3MG | 220°C | 〇 | 〇 | 〇 | - |
CKF3M | 350°C | 〇 | 〇 | 〇 | - |
CKF3R | 150°C | - | 〇 | 〇 | 〇 |
CKF3MG | 350°C | 〇 | 〇 | 〇 | - |
CKF3RG | 150°C | - | 〇 | 〇 | 〇 |
For use with fluids other than steam, hot water, water, or air, please contact us.
Simple installation in either vertical or horizontal pipelines.
Can be installed on both horizontal and vertical piping. Furthermore, in vertical piping, it can be used not only for downward flow, but also for upward flow. In other words, there are no restrictions on the installation position. Furthermore, its smart and compact shape with no protrusions enables clean piping design.
Comparison with swing-type check valves
Swing-type check valves open under their own weight when the pressure difference between the primary and secondary sides becomes small, allowing.
Flangeless (wafer) type installation
The CKF3 series is a flangeless, or wafer, type check valve. It is connected by inserting it between pipe flanges, enabling compact installation.
The outer part of the body is equipped with self-centering fins, so the valve is automatically centered when installed.